{"product_id":"launch-x431-oscilloscope-o2-2","title":"LAUNCH X431 Oscilloscope O2-2","description":"\u003ch3 data-section-id=\"1erjiqe\" data-start=\"95\" data-end=\"142\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"99\" data-end=\"142\"\u003eLAUNCH X-431 O2-2 Oscilloscope Scopebox\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"144\" data-end=\"216\"\u003e\u003cstrong data-start=\"144\" data-end=\"216\"\u003eAdvanced 4-Channel Automotive Oscilloscope for Precision Diagnostics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"218\" data-end=\"536\"\u003eThe LAUNCH X-431 O2-2 Scopebox is a powerful, portable 4-channel digital oscilloscope designed to elevate your automotive diagnostics. As an optional module for X-431 series scan tools, it transforms your device into a professional lab scope, enabling in-depth analysis of electrical systems and rapid fault detection.\u003c\/p\u003e\n\u003chr data-start=\"538\" data-end=\"541\"\u003e\n\u003ch3 data-section-id=\"zn41ep\" data-start=\"543\" data-end=\"581\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"547\" data-end=\"581\"\u003eProfessional-Grade Diagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"583\" data-end=\"893\"\u003eEngineered for modern vehicles, the O2-2 Scopebox allows technicians to analyze electrical signals from circuits, sensors, actuators, and ignition systems. By visualizing waveform data, it helps quickly identify complex electrical faults, reducing diagnostic time and eliminating unnecessary parts replacement.\u003c\/p\u003e\n\u003chr data-start=\"895\" data-end=\"898\"\u003e\n\u003ch3 data-section-id=\"pm8yra\" data-start=\"900\" data-end=\"920\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"904\" data-end=\"920\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"922\" data-end=\"2111\"\u003e\n\u003cli data-section-id=\"u6btqk\" data-start=\"922\" data-end=\"1066\"\u003e\n\u003cstrong data-start=\"924\" data-end=\"960\"\u003e4-Channel High-Performance Scope\u003c\/strong\u003e\u003cbr data-start=\"960\" data-end=\"963\"\u003eSimultaneously analyze multiple signals with ultra-fast sampling up to 1 GSa\/s and 100 MHz bandwidth.\u003c\/li\u003e\n\u003cli data-section-id=\"19gjn1x\" data-start=\"1068\" data-end=\"1219\"\u003e\n\u003cstrong data-start=\"1070\" data-end=\"1100\"\u003eExtensive Waveform Library\u003c\/strong\u003e\u003cbr data-start=\"1100\" data-end=\"1103\"\u003eBuilt-in known-good waveforms with automatic setup across all four channels for faster, more accurate diagnostics.\u003c\/li\u003e\n\u003cli data-section-id=\"1kew0ki\" data-start=\"1221\" data-end=\"1352\"\u003e\n\u003cstrong data-start=\"1223\" data-end=\"1253\"\u003eAdvanced Trigger Functions\u003c\/strong\u003e\u003cbr data-start=\"1253\" data-end=\"1256\"\u003eCapture intermittent faults and glitches with precision using edge and pulse width triggering.\u003c\/li\u003e\n\u003cli data-section-id=\"1jh4iaw\" data-start=\"1354\" data-end=\"1475\"\u003e\n\u003cstrong data-start=\"1356\" data-end=\"1383\"\u003ePlug \u0026amp; Play Convenience\u003c\/strong\u003e\u003cbr data-start=\"1383\" data-end=\"1386\"\u003ePre-installed software on compatible X-431 devices—no additional installation required.\u003c\/li\u003e\n\u003cli data-section-id=\"1vkar4n\" data-start=\"1477\" data-end=\"1617\"\u003e\n\u003cstrong data-start=\"1479\" data-end=\"1512\"\u003eIndependent Channel Grounding\u003c\/strong\u003e\u003cbr data-start=\"1512\" data-end=\"1515\"\u003eEach channel features independent grounding for cleaner signals and protection against interference.\u003c\/li\u003e\n\u003cli data-section-id=\"kzxiio\" data-start=\"1619\" data-end=\"1727\"\u003e\n\u003cstrong data-start=\"1621\" data-end=\"1652\"\u003eHigh-Quality BNC Connectors\u003c\/strong\u003e\u003cbr data-start=\"1652\" data-end=\"1655\"\u003eTwist \u0026amp; lock design ensures secure, stable connections during testing.\u003c\/li\u003e\n\u003cli data-section-id=\"1066puu\" data-start=\"1729\" data-end=\"1847\"\u003e\n\u003cstrong data-start=\"1731\" data-end=\"1760\"\u003eBuilt-in Signal Generator\u003c\/strong\u003e\u003cbr data-start=\"1760\" data-end=\"1763\"\u003eIntegrated square wave generator for calibration verification and accuracy checks.\u003c\/li\u003e\n\u003cli data-section-id=\"1sg52lv\" data-start=\"1849\" data-end=\"1980\"\u003e\n\u003cstrong data-start=\"1851\" data-end=\"1883\"\u003eWaveform Playback \u0026amp; Analysis\u003c\/strong\u003e\u003cbr data-start=\"1883\" data-end=\"1886\"\u003eRecord, store, and replay waveforms with adjustable playback speed for detailed examination.\u003c\/li\u003e\n\u003cli data-section-id=\"t60qk6\" data-start=\"1982\" data-end=\"2111\"\u003e\n\u003cstrong data-start=\"1984\" data-end=\"2017\"\u003eComprehensive Signal Analysis\u003c\/strong\u003e\u003cbr data-start=\"2017\" data-end=\"2020\"\u003eEvaluate amplitude, waveform shape, pulse width, and frequency characteristics with ease.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2113\" data-end=\"2116\"\u003e\n\u003ch3 data-section-id=\"n07754\" data-start=\"2118\" data-end=\"2139\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2122\" data-end=\"2139\"\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2141\" data-end=\"2163\"\u003eWorks seamlessly with:\u003c\/p\u003e\n\u003cul data-start=\"2164\" data-end=\"2223\"\u003e\n\u003cli data-section-id=\"1m3g1i6\" data-start=\"2164\" data-end=\"2189\"\u003eLAUNCH X-431 Throttle\u003c\/li\u003e\n\u003cli data-section-id=\"102p0j4\" data-start=\"2190\" data-end=\"2223\"\u003eLAUNCH X-431 PAD II \/ PAD III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2225\" data-end=\"2228\"\u003e\n\u003ch3 data-section-id=\"gqkziz\" data-start=\"2230\" data-end=\"2262\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2234\" data-end=\"2262\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2264\" data-end=\"3118\"\u003e\n\u003cli data-section-id=\"1ku1meu\" data-start=\"2264\" data-end=\"2283\"\u003e\n\u003cstrong data-start=\"2266\" data-end=\"2279\"\u003eChannels:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli data-section-id=\"1yq5rjn\" data-start=\"2284\" data-end=\"2310\"\u003e\n\u003cstrong data-start=\"2286\" data-end=\"2300\"\u003eBandwidth:\u003c\/strong\u003e 100 MHz\u003c\/li\u003e\n\u003cli data-section-id=\"79ufj3\" data-start=\"2311\" data-end=\"2356\"\u003e\n\u003cstrong data-start=\"2313\" data-end=\"2333\"\u003eMax Sample Rate:\u003c\/strong\u003e 1 GSa\/s (4 channels)\u003c\/li\u003e\n\u003cli data-section-id=\"10r914w\" data-start=\"2357\" data-end=\"2394\"\u003e\n\u003cstrong data-start=\"2359\" data-end=\"2373\"\u003eRise Time:\u003c\/strong\u003e ≤ 3.5 ns (typical)\u003c\/li\u003e\n\u003cli data-section-id=\"u5k4lv\" data-start=\"2395\" data-end=\"2430\"\u003e\n\u003cstrong data-start=\"2397\" data-end=\"2417\"\u003eInput Impedance:\u003c\/strong\u003e 1 MΩ ±1.5%\u003c\/li\u003e\n\u003cli data-section-id=\"101l31n\" data-start=\"2431\" data-end=\"2470\"\u003e\n\u003cstrong data-start=\"2433\" data-end=\"2451\"\u003eStorage Depth:\u003c\/strong\u003e 50M (4 channels)\u003c\/li\u003e\n\u003cli data-section-id=\"llw7ue\" data-start=\"2471\" data-end=\"2496\"\u003e\n\u003cstrong data-start=\"2473\" data-end=\"2488\"\u003eResolution:\u003c\/strong\u003e 8-bit\u003c\/li\u003e\n\u003cli data-section-id=\"k36i9d\" data-start=\"2498\" data-end=\"2536\"\u003e\n\u003cstrong data-start=\"2500\" data-end=\"2518\"\u003eVoltage Range:\u003c\/strong\u003e 5 mV – 10 V\/div\u003c\/li\u003e\n\u003cli data-section-id=\"bcun2b\" data-start=\"2537\" data-end=\"2632\"\u003e\n\u003cstrong data-start=\"2539\" data-end=\"2556\"\u003eOffset Range:\u003c\/strong\u003e\n\u003cul data-start=\"2561\" data-end=\"2632\"\u003e\n\u003cli data-section-id=\"s0vui6\" data-start=\"2561\" data-end=\"2595\"\u003e±2.5 V (\u0026lt;500 mV\/div, probe x1)\u003c\/li\u003e\n\u003cli data-section-id=\"h000p9\" data-start=\"2598\" data-end=\"2632\"\u003e±120 V (≥500 mV\/div, probe x1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3da4lv\" data-start=\"2634\" data-end=\"2715\"\u003e\n\u003cstrong data-start=\"2636\" data-end=\"2649\"\u003eTimebase:\u003c\/strong\u003e\n\u003cul data-start=\"2654\" data-end=\"2715\"\u003e\n\u003cli data-section-id=\"psj2l5\" data-start=\"2654\" data-end=\"2682\"\u003e50 ns – 1 ks (1 channel)\u003c\/li\u003e\n\u003cli data-section-id=\"j3l4u0\" data-start=\"2685\" data-end=\"2715\"\u003e200 ns – 1 ks (4 channels)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ei9tcw\" data-start=\"2717\" data-end=\"2750\"\u003e\n\u003cstrong data-start=\"2719\" data-end=\"2741\"\u003eTimebase Accuracy:\u003c\/strong\u003e 20 ppm\u003c\/li\u003e\n\u003cli data-section-id=\"1h62azc\" data-start=\"2752\" data-end=\"2785\"\u003e\n\u003cstrong data-start=\"2754\" data-end=\"2776\"\u003eAcquisition Modes:\u003c\/strong\u003e Normal\u003c\/li\u003e\n\u003cli data-section-id=\"8vh6uv\" data-start=\"2786\" data-end=\"2826\"\u003e\n\u003cstrong data-start=\"2788\" data-end=\"2806\"\u003eTrigger Types:\u003c\/strong\u003e Edge, Pulse Width\u003c\/li\u003e\n\u003cli data-section-id=\"cr0x5o\" data-start=\"2827\" data-end=\"2870\"\u003e\n\u003cstrong data-start=\"2829\" data-end=\"2847\"\u003eTrigger Modes:\u003c\/strong\u003e Auto, Normal, Single\u003c\/li\u003e\n\u003cli data-section-id=\"117yf0r\" data-start=\"2871\" data-end=\"2914\"\u003e\n\u003cstrong data-start=\"2873\" data-end=\"2886\"\u003eCoupling:\u003c\/strong\u003e DC \/ AC \/ Noise Rejection\u003c\/li\u003e\n\u003cli data-section-id=\"1jww2rq\" data-start=\"2916\" data-end=\"2951\"\u003e\n\u003cstrong data-start=\"2918\" data-end=\"2940\"\u003eProtocol Decoding:\u003c\/strong\u003e CAN, LIN\u003c\/li\u003e\n\u003cli data-section-id=\"12r1h27\" data-start=\"2953\" data-end=\"2990\"\u003e\n\u003cstrong data-start=\"2955\" data-end=\"2973\"\u003eDisplay Modes:\u003c\/strong\u003e YT, Zoom, Roll\u003c\/li\u003e\n\u003cli data-section-id=\"1l5ky75\" data-start=\"2991\" data-end=\"3033\"\u003e\n\u003cstrong data-start=\"2993\" data-end=\"3007\"\u003eRoll Mode:\u003c\/strong\u003e 200 ms\/div – 1000 s\/div\u003c\/li\u003e\n\u003cli data-section-id=\"53iga0\" data-start=\"3035\" data-end=\"3076\"\u003e\n\u003cstrong data-start=\"3037\" data-end=\"3063\"\u003eOperating Temperature:\u003c\/strong\u003e 0°C ~ 50°C\u003c\/li\u003e\n\u003cli data-section-id=\"lrahps\" data-start=\"3077\" data-end=\"3118\"\u003e\n\u003cstrong data-start=\"3079\" data-end=\"3103\"\u003eStorage Temperature:\u003c\/strong\u003e -30°C ~ 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3120\" data-end=\"3123\"\u003e\n\u003ch3 data-section-id=\"1409h46\" data-start=\"3125\" data-end=\"3162\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3129\" data-end=\"3162\"\u003eWhy Choose the O2-2 Scopebox?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3164\" data-end=\"3371\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3164\" data-end=\"3216\"\u003eDiagnose faster. Analyze deeper. Repair smarter.\u003c\/strong\u003e\u003cbr data-start=\"3216\" data-end=\"3219\"\u003eThe LAUNCH X-431 O2-2 is the ultimate tool for technicians who demand accuracy, efficiency, and advanced electrical diagnostics in one compact solution.\u003c\/p\u003e","brand":"Launch","offers":[{"title":"Default Title","offer_id":43402653925435,"sku":"LC52120002","price":619.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/2325\/8171\/files\/1_1.jpg?v=1776687952","url":"https:\/\/www.launchx431pro.com\/products\/launch-x431-oscilloscope-o2-2","provider":"Launchx431pro EU","version":"1.0","type":"link"}